Tender Detail

Corrigendum - 2 Published On : 12/09/2025
Corrigendum Details : Deadline has been changes from Sep 11 2025 12:00AM to Sep 18 2025 12:00AM
Bid Auto Extn Corrigendum
Corrigendum Document : Can be viewed by Subscribers
Corrigendum - 1 Published On : 29/08/2025
Corrigendum Details : Other
Corrigendum Document : Can be viewed by Subscribers
Buyer/Seller : Can be viewed by Subscribers |
DID : 86950262
Requirement : CWE/P-49/2025-26
COMPREHENSIVE MAINTENANCE OF AIR CONDITIONER PLANT/ SPLITS AND WINDOW TYPE AIR CONDITIONER UNDER GE (W) PATHANKOT, COMPREHENSIVE MAINTENANCE OF AIR CONDITIONER PLANT/ SPLITS AND WINDOW TYPE AIR CONDITIONER UNDER GE (W) PATHANKOT, S& F in replacement of Contactor ML-1 coil voltage 240V, 16 Amps size as per existing all as specified and directed, S&F Split type AC outdoor unit fan grill/jalli in round/square shape of size 18"x18" made of PVC material, fixing with suitable size screws complete all as specified and directed, S&F in replacement copper pipe of dia 3/8 inch fixed in repair complete all as specified and directed, S&F in replacement 3 phase digital type voltmeter with in built selector switch, LED display, accuracy class 1.0, flush mounting on LT Panel complete all as specified and directed, S&F in replacement condensing fan blade for window type AC of capacity upto 2 Ton as per exisitng size complete all as specified and directed, S&F in replacement of unsv 4way reversing valve kit to maintain the desired temperature of cooling system of window type AC /split type AC of capacity 1.5/2 Ton as per site requirement including gas charging complete all as specified and directed, Dismantling the condensor unit of 7 Ton AC plant after carefully disconnecting electrical connections, opening and removing fan motor of size 1Hp transporting to civil motor workshop, removing burnt winding wire and rewinding with super enamalled copper wire of appropriate gauge with insulating material complete including servicing, varnishing, replacement of bearing housing and bearings, greasing of shaft, reassembling and transporting back to site and installing at original location including making all the connections and testing complete all as specified and directed, Dismantling of AHU motor of 15 HP three phase after carefully disconnecting the electrical connections, transporting to workshop and rewinding with super enamalled copper wire of appropriate gauge with insulating material complete after removing old burnt winding wire including servicing, varnishing changing the bearing/ Bush & shaft and transporting back from workshop and installing at site including testing complete all as specified and directed, S&F in replacement Blower for split type AC of capacity capacity upto 2 Ton complete all as specified and directed, S&F in replacement Cast iron Y -type pot stainer flanged ends to BS 10 table 'F', S.S 304 with perforated sheet screen of size ø100mm complete all as specified and directed, S&F PVC round sheathed copper conductor cable of size 2.5 Sqmm 3 core fixed in repair complete all as specified and directed, Supplying and laying in replacement synthetic Rubber insulated mats 2 mm thick for voltage upto 3.3 kv for electrical purpose as per IS 15652-2006, suitable for electrical shock safety of sizes 2m x 1m, complete all as specified and directed, S&F in replacement condensing coil for split type AC of capacity upto 2 Ton including gas charging complete all as specified and directed, S&F in replacement of MCCB 63 Amps, 4 pole 25 KA rupturing capacity fixing in position and making conection with bus bar with suitable size Aluminium spreader links including testing on load, complete all as specified and directed, Supply & charging Refrigerant R-22 to Air conditioner (window type /split type) of any capacity and make all as specified and directed. Make - Mafron, Supply & Charging Refrigerant R - 410 to Air conditioner (window type /split type )of any capacity and make complete all as specified and directed. Make - Mafron, S&F in replacement copper pipe of dia 1/4 inch fixed in repair complete all as specified and directed, Servicing of window type AC/ split type AC of capacity 1.5/2 ton of any make at site with complete washing/ removing of dust from blower fan and necessary oiling the blower motor complete all as specified and directed, S&F in replacement of PCB circuit for INVERTER AC hot and cold for split type AC of capacity upto 2 Ton of existing makes of AC complete all as specified and directed, S&F in replacement Front grill of window AC, capacity 1.5/2 ton suitable for make LG/ Carrier/ Sidwal/ Whirlpool as per existing fixed in repair complete all as specified and directed, M&L in replacement for providing and fixing 10mm thick plaster of Paris ceiling (Gypsum anhydrous) to flat surface over aluminium cladding and reinforced with G.I. wire mesh incl fillets, metal frame work complete all as specified and directed, Removing the air vent of AC duct by unscrewing the nuts, cleaning the duct of size upto 600x600mm by creating negative vaccum pressure, removing the dust by using revovling brush and air whipping tools to stir movement of settled dust and refixing the air vents, complete all as specified and directed, Dismantling of compressor motor of 75 HP three phase squirrel cage induction type after carefully disconnecting the electrical connections, lifting and transporting to workshop, cleaning and greasing of motor shaft and bearings including replacment of worn out seal & gasket, reassembling and transporting back to the site and refixing at original location incl complete connections and testing complete all as specified and directed, S&F in replacement Swing motor for split type AC of capacity upto 2.0 ton as per existing make, complete all as specified and directed, M&L for GI tubing (ISI Marked) for medium grade 20mm bore for cooling tower fixed on wall complete including all the necessary fittings to hold the pipe along the wall like hook, bolts etc incl taking down old unsv GI tubing any type complete all as specified and directed, S&F in replacement of UNSV Remote control with two AAA battery for split type AC of capacity 1.5 ton/ 2 ton suitable for make of LG/ Carrier/ Sidwal/ Whirlpool as per existing complete all as specified and directed, Cleaning of AHU of AC plant of size upto 10 Ton by removing the dust with chemical washing the fins, copper coil, fire damper blades using pressure jet, opening of AHU fan including pully and belt, cleaning fan blades, greasing of fan shaft and bearing, reassembling fan blades, shaft, pully and belt complete all as specified and directed, S&F in replacement condensing fan of window type AC of capacity 1.5/2 ton as per existing fixed in repair complete all as specified and directed, Taking down defective indoor Unit for Split AC 1.5 / 2 Ton and replacing the same with new for existing make of AC complete all as specified and directed, M&L for replacement of compressor oil (servo) for AC plant, complete all as specified and directed, Supply & Charging Refrigerant R -134A complete one time for top up or making full qty as per pressure requirment of plant and testing for any leakage and rectifying the same all as specified and directed, S&F in replacement of unsv condensing coil for window type AC of capacity upto 2 Ton including gas charging, complete all as specified and directed, S&F in replacement 3 phase digital type ammeter with in built selector switch, LED display, accuracy class 1.0, flush mounting on LT Panel complete all as specified and directed, Taking down condensor fan motor of window/split type AC of capacity upto 2 Ton, removing the burnt motor winding wire of any type, rewding the motor with super enamalled copper wire of appropriate gauge including varnishing, replacement of bearing housing and bearings, greasing of shaft, reassembling and refixing including making all the connections and testing complete all as specified and directed, Supply & Instalation , commosioning,testing microprocessor-based control panel for the 50 Ton AC Plant Make (voltas). with automates the operation of the compressor, condenser fans, AHU, pumps, and monitors temperature, pressure, and alarms. Able to improves system efficiency, safety, and enables remote integration via BMS (Building Management System).and including following componet with their Microprocessor Controller (PLC/ Embedde
Tender description : CWE/P-49/2025-26 #*. COMPREHENSIVE MAINTENANCE OF AIR CONDITIONER PLANT/ SPLITS AND WINDOW TYPE AIR CONDITIONER UNDER GE (W) PATHANKOT
Company Industry: Security Services

Key values

Document fees : INR 500
EMD : INR 20,000
Tender Estimated cost : INR 1,000,000
Closing date : 18/09/2025
Location : India-Punjab

Tender Documents

Top